Trace the installed branch from its
defined source to the vessel

2
00:00:04.534 --> 00:00:07.913
connection against the controlled piping
diagram.

3
00:00:08.033 --> 00:00:10.516
Check the specified route, isolation

4
00:00:10.636 --> 00:00:13.175
and identifiers using safe methods.

5
00:00:13.295 --> 00:00:16.467
Do not assume a pipe has the intended
contents

6
00:00:16.587 --> 00:00:18.932
because its colour looks familiar.

7
00:00:19.052 --> 00:00:24.086
A label and the actual connection must
agree with the system information.

8
00:00:24.706 --> 00:00:27.672
For fixed pipework, contents
identification

9
00:00:27.792 --> 00:00:31.378
and applicable flow direction help prevent
mistakes.

10
00:00:31.498 --> 00:00:35.153
Compare labels with the route and
controlled drawing,

11
00:00:35.273 --> 00:00:37.687
including places where lines cross.

12
00:00:37.807 --> 00:00:42.497
A correct label on the wrong connected
branch remains a discrepancy.

13
00:00:42.617 --> 00:00:45.238
Record the location so the engineering

14
00:00:45.358 --> 00:00:47.978
team can resolve the actual connection

15
00:00:48.098 --> 00:00:50.788
rather than merely replacing the label.

16
00:00:51.408 --> 00:00:53.891
The branch may be installed as drawn

17
00:00:54.011 --> 00:00:58.493
while the required utility-quality
evidence is still unavailable.

18
00:00:58.613 --> 00:01:00.958
Record those as separate statuses.

19
00:01:01.078 --> 00:01:04.113
A pressure indication alone cannot
establish

20
00:01:04.233 --> 00:01:07.305
chemical or microbiological suitability.

21
00:01:07.425 --> 00:01:10.873
Determine what qualification and sampling
evidence

22
00:01:10.993 --> 00:01:15.545
applies to the intended use through the
approved project approach,

23
00:01:15.665 --> 00:01:20.010
rather than borrowing limits from an
unrelated sterile process.

24
00:01:20.630 --> 00:01:23.802
A late branch addition may affect the
upstream

25
00:01:23.922 --> 00:01:26.612
system as well as the receiving vessel.

26
00:01:26.732 --> 00:01:29.164
Identify the changed configuration

27
00:01:29.284 --> 00:01:31.767
and assess the required installation

28
00:01:31.887 --> 00:01:34.231
and other verification before use.

29
00:01:34.351 --> 00:01:37.041
Do not assume that the original utility

30
00:01:37.161 --> 00:01:40.276
qualification covers every future
extension.

31
00:01:40.396 --> 00:01:42.534
Our workbook asks which records

32
00:01:42.654 --> 00:01:47.757
and responsible system owners must be
linked before closing the interface.